maple-systems HMI5043LB
maple-systems HMI5043LB-Bundle
maple-systems HMI5043LB-Case16
maple-systems HMI5070DL
maple-systems HMI5070L
maple-systems HMI5070L-Bundle
maple-systems HMI5070L-Case16
maple-systems HMI5070LB
maple-systems HMI5070LB-Bundle
maple-systems HMI5070LB-Case16
maple-systems HMI5070NL
maple-systems HMI5070P
maple-systems HMI5070R
maple-systems HMI5071L
maple-systems HMI5097DXL
maple-systems HMI5097NXL
maple-systems HMI5100L
maple-systems HMI5102L
maple-systems HMI5103L
maple-systems HMI5121XL
maple-systems HMI5121P
maple-systems HMI5150XL
maple-systems HMI5150P
POTTER & BRUMFIELD KUP14DEI-24 USPP KUP14DEI24
POTTER & BRUMFIELD KUP-14D55-24 NSFP KUP14D5524
POTTER & BRUMFIELD KUP-14D45-24 USPP KUP14D4524
POTTER & BRUMFIELD KUP-14A35-120 USPP KUP14A35120
POTTER & BRUMFIELD KUP-14A25-120 USPP KUP14A25120
POTTER & BRUMFIELD KUP-14A15-120 USPP KUP14A15120
POTTER & BRUMFIELD KUP-11D15-24 USPP KUP11D1524
POTTER & BRUMFIELD KUP-11D15-24 NSPP KUP11D1524
POTTER & BRUMFIELD KUP-11D15-24 NSFP KUP11D1524
POTTER & BRUMFIELD KUP-11A15-240 USPP KUP11A15240
POTTER & BRUMFIELD KUP-11A15-120 USPP KUP11A15120
POTTER & BRUMFIELD KUMP-11A18-240 NSPP KUMP11A18240
POTTER & BRUMFIELD KUL-4077 USPP KUL4077
POTTER & BRUMFIELD KUL-4072-120 USPP KUL4072120
POTTER & BRUMFIELD KUEP-11A15-120 USPP KUEP11A15120
POTTER & BRUMFIELD KU-5591-1 USPP KU55911
POTTER & BRUMFIELD KU-5497 USPP KU5497
POTTER & BRUMFIELD KU-4489 USPP KU4489
POTTER & BRUMFIELD KRPA-14AG-120 USPP KRPA14AG120
POTTER & BRUMFIELD KRPA-11DG-48 NSPP KRPA11DG48
POTTER & BRUMFIELD KRPA-11DG-12 USPP KRPA11DG12
POTTER & BRUMFIELD KRPA-11DG-110 USPP KRPA11DG110
POTTER & BRUMFIELD KRPA-11AN-120 NSPP KRPA11AN120
POTTER & BRUMFIELD KRPA-11AG-120 USPP KRPA11AG120
POTTER & BRUMFIELD KRP-5DG-24 NSPP KRP5DG24
POTTER & BRUMFIELD KRP-14DG-24 USPP KRP14DG24
POTTER & BRUMFIELD KRP-14DG-24 NSPP KRP14DG24
POTTER & BRUMFIELD KRP-14DG-24 NSFP KRP14DG24
POTTER & BRUMFIELD KRP-14AY-120 USPP KRP14AY120
POTTER & BRUMFIELD KRP-11DG-24 USPP KRP11DG24
POTTER & BRUMFIELD KRP-11DG-24 NSFP KRP11DG24
POTTER & BRUMFIELD KRP-11DG USPP KRP11DG
POTTER & BRUMFIELD KRP-11A-24 USPP KRP11A24
POTTER & BRUMFIELD KR-5737-4 USPP KR57374
POTTER & BRUMFIELD KHU-17D12-24 USPP KHU17D1224
POTTER & BRUMFIELD KHU-17A11-120 NSPP KHU17A11120
POTTER & BRUMFIELD KHU-11D11-12 USPP KHU11D1112
POTTER & BRUMFIELD KHAU-17D11-6 USPP KHAU17D116
POTTER & BRUMFIELD KHAU-17D11-6 FNFP KHAU17D116
POTTER & BRUMFIELD KHAU-17D11-110 USPP KHAU17D11110
POTTER & BRUMFIELD KH-5918 USPP KH5918
POTTER & BRUMFIELD KH-500-1-DC24 USPP KH5001DC24
POTTER & BRUMFIELD KA4471 USPP KA4471
POTTER & BRUMFIELD KA-4008-3 USPP KA40083
POTTER & BRUMFIELD K10P11D5512 FNFP K10P11D5512
POTTER & BRUMFIELD K10P-11A15-120 USPP K10P11A15120
POTTER & BRUMFIELD IDC-5 USPP IDC5
POTTER & BRUMFIELD IDC-5 NSPP IDC5
POTTER & BRUMFIELD IDC-5 NSFP IDC5
POTTER & BRUMFIELD IDC-24 NSFP IDC24
POTTER & BRUMFIELD IACM-5 USPP IACM5
POTTER & BRUMFIELD HP-4110-24V NSPP HP411024V
POTTER & BRUMFIELD 27E893 USPP 27E893
POTTER & BRUMFIELD 27E126 NSPP 27E126
POTTER & BRUMFIELD 27E122 USPP 27E122
POTTER & BRUMFIELD 14503654-001 USPP 14503654001
POSIFLATE 4023070 NSPP 4023070
POSIFLATE 4023056 USPP 4023056
POSIFLATE 4023054 USPP 4023054
POSIFLATE 4023054 NSPP 4023054
POSIFLATE 1056800 NSFP 1056800
PORTSTRAINMETERCONTROLLERINFCS-011B
PORTSTRAINMETERCONTROLLERINFCS-011B
PORTSTRAINMETERCONTROLLERINFCS-000B
PORTSTRAINMETERCONTROLLERINFCS-000B
PNEUMADYNE代理 PNEUMADYNE經銷 PNEUMADYNE廠家 PNEUMADYNE辦事處 PNEUMADYNE現貨 PNEUMADYNE庫存 PNEUMADYNE價格 PNEUMADYNE型號 PNEUMADYNE中國 PNEUMADYNE北京辦事處
DC-VG-1
WOERNER分配器 VPB-B6/P(VPB-B/6/0/0/M3/20/14/20/P)
stonel限位開關 QX2VE02SRA
stonel限位開關 EN33D05RA
stonel限位開關 QX50E02SCA
供應美國Protection Controls,Protection Controls火焰檢測器,Protection Controls 燃燒控制器
Protection Controls, Inc.公司成立于1953年,生產電氣防爆設備,防止爆炸和隨后氣體點燃在密閉空間對身體傷害和財產造成損害的保護控制。
優勢供應美國Protection Controls火焰檢測器,Protection Controls 燃燒控制器 ,Protection Controls繼電器 ,Protection Controls點火變壓器,Protection Controls 安全控制器
常用型號: SS100A SS108A DP100 DELAY PAK SST PLUG-IN PURGE TIMER U300A U300M A06 A10 A10-LA2 C06-SA6 SS3CP SS3CPD SS4CP 6642VA 6642VB 6642VBL 6642VBLNR 6642VBLT 6642VBLT/NR 6642VBNR 6642VBT/NR 6642VL 6642VLT 6642VT 7256-AH 7256-AHE 7256-B 7256-B10 7256-B10E 7256-B10H 7256-B10HE 7256-B10NR 7256-B10NRE 7256-B10NRH 7256-B10NRHE 7256-B5 7256-B5E 7256-B5H 7256-B5HE 7256-B5NR 7256-B5NRE 7256-B5NRH 7256-B5NRHE 7256-BE 7256-BH 7256-BHE 7256-BNR 7256-BNRE 7256-BNRH 7256-BNRHE 7256-BT-10NR 7256-BT-10NRE 7256-BT-10NRH 7256-BT-10NRHE 7256-BT-15NR 7256-BT-15NRE 7256-BT-15NRH 7256-BT-15NRHE 7256-BT-5NR 7256-BT-5NRE 7256-BT-5NRH 7256-BT-5NRHE 8966 TELE FAULT II FIRT OUTAGE 6642VL 6642VLT 76057-B 5909N-8 IGNITIFIER PCI 6642VA PCI 6642VBT PCI 6642VLT PCI 6642VT
SS100A
ACF RELAY
P-CII
SS3CP
A-60-15
6642-VBT-NR
P-C II U-V SCANNER
P-C II W U-V SCANNER
P-C II WRA U-V SCANNER
P-CII U-V SCANNER
P-CII W U-V SCANNER
P-CII WRA U-V SCANNER
P-CIIW U-V SCANNER
P-CIIWRA U-V SCANNER
繼電器:
2AC 200V RELAY
2AC 230V RELAY
ACF RELAY
TCL RELAY
LR100 RELAY
ACF CHECK RELAY
SS100A FLAME PAK
SS108A FLAME PAK
DP100 DELAY PAK
SST PLUG-IN PURGE TIMER
U300A TIMOFIER
U300M TIMOFIER
變壓器, 點火變壓器:
A06 IGNITION TRANSFORMER
A10 IGNITION TRANSFORMER
A10-LA2 IGNITION TRANSFORMER
C06-SA6 IGNITION TRANSFORMER
SS3CP TRANSFORMER
SS3CPD TRANSFORMER
SS4CP TRANSFORMER
燃燒控制器:
6642VA PROTECTOFIER
6642VB PROTECTOFIER
6642VBL PROTECTOFIER
6642VBLNR PROTECTOFIER
6642VBLT PROTECTOFIER
6642VBLT/NR PROTECTOFIER
6642VBNR PROTECTOFIER
6642VBT/NR PROTECTOFIER
6642VL PROTECTOFIER
6642VLT PROTECTOFIER
6642VT PROTECTOFIER
FORM 7256-AH PROTECTOFIER
7256-AHE PROTECTOFIER
7256-B PROTECTOFIER
7256-B10 PROTECTOFIER
7256-B10E PROTECTOFIER
7256-B10H PROTECTOFIER
7256-B10HE PROTECTOFIER
7256-B10NR PROTECTOFIER
7256-B10NRE PROTECTOFIER
7256-B10NRH PROTECTOFIER
7256-B10NRHE PROTECTOFIER
7256-B5 PROTECTOFIER
7256-B5E PROTECTOFIER
7256-B5H PROTECTOFIER
7256-B5HE PROTECTOFIER
7256-B5NR PROTECTOFIER
7256-B5NRE PROTECTOFIER
7256-B5NRH PROTECTOFIER
7256-B5NRHE PROTECTOFIER
7256-BE PROTECTOFIER
7256-BH PROTECTOFIER
7256-BHE PROTECTOFIER
7256-BNR PROTECTOFIER
7256-BNRE PROTECTOFIER
7256-BNRH PROTECTOFIER
7256-BNRHE PROTECTOFIER
7256-BT-10NR PROTECTOFIER
7256-BT-10NRE PROTECTOFIER
7256-BT-10NRH PROTECTOFIER
7256-BT-10NRHE PROTECTOFIER
7256-BT-15NR PROTECTOFIER
7256-BT-15NRE PROTECTOFIER
7256-BT-15NRH PROTECTOFIER
7256-BT-15NRHE PROTECTOFIER
7256-BT-5NR PROTECTOFIER
7256-BT-5NRE PROTECTOFIER
7256-BT-5NRH PROTECTOFIER
7256-BT-5NRHE PROTECTOFIER
FORM 8966 TELE FAULT II FIRT OUTAGE
FORM 6642VL
FORM 6642VLT PROTECTOFIER
FORM 76057-B PROTECTOFIER
FORM 5909N-8 IGNITIFIER
PCI 6642VA PROTECTOFIER
PCI 6642VBT PROTECTOFIER
PCI 6642VLT PROTECTOFIER
PCI 6642VT PROTECTOFIER
火焰檢測器:
P-C II U-V SCANNER
P-C II W U-V SCANNER
P-C II WRA U-V SCANNER
P-CII U-V SCANNER
P-CII W U-V SCANNER
P-CII WRA U-V SCANNER
P-CIIW U-V SCANNER
P-CIIWRA U-V SCANNER
繼電器:
2AC 200V RELAY
2AC 230V RELAY
ACF RELAY
TCL RELAY
LR100 RELAY
ACF CHECK RELAY
SS100A FLAME PAK
SS108A FLAME PAK
DP100 DELAY PAK
SST PLUG-IN PURGE TIMER
U300A TIMOFIER
U300M TIMOFIER
變壓器, 點火變壓器:
A06 IGNITION TRANSFORMER
A10 IGNITION TRANSFORMER
A10-LA2 IGNITION TRANSFORMER
C06-SA6 IGNITION TRANSFORMER
SS3CP TRANSFORMER
SS3CPD TRANSFORMER
SS4CP TRANSFORMER
燃燒控制器:
6642VA PROTECTOFIER
6642VB PROTECTOFIER
6642VBL PROTECTOFIER
6642VBLNR PROTECTOFIER
6642VBLT PROTECTOFIER
6642VBLT/NR PROTECTOFIER
6642VBNR PROTECTOFIER
6642VBT/NR PROTECTOFIER
6642VL PROTECTOFIER
6642VLT PROTECTOFIER
6642VT PROTECTOFIER
FORM 7256-AH PROTECTOFIER
7256-AHE PROTECTOFIER
7256-B PROTECTOFIER
7256-B10 PROTECTOFIER
7256-B10E PROTECTOFIER
7256-B10H PROTECTOFIER
7256-B10HE PROTECTOFIER
7256-B10NR PROTECTOFIER
7256-B10NRE PROTECTOFIER
7256-B10NRH PROTECTOFIER
7256-B10NRHE PROTECTOFIER
7256-B5 PROTECTOFIER
7256-B5E PROTECTOFIER
7256-B5H PROTECTOFIER
7256-B5HE PROTECTOFIER
7256-B5NR PROTECTOFIER
7256-B5NRE PROTECTOFIER
7256-B5NRH PROTECTOFIER
7256-B5NRHE PROTECTOFIER
7256-BE PROTECTOFIER
7256-BH PROTECTOFIER
7256-BHE PROTECTOFIER
7256-BNR PROTECTOFIER
7256-BNRE PROTECTOFIER
7256-BNRH PROTECTOFIER
7256-BNRHE PROTECTOFIER
7256-BT-10NR PROTECTOFIER
7256-BT-10NRE PROTECTOFIER
7256-BT-10NRH PROTECTOFIER
7256-BT-10NRHE PROTECTOFIER
7256-BT-15NR PROTECTOFIER
7256-BT-15NRE PROTECTOFIER
7256-BT-15NRH PROTECTOFIER
7256-BT-15NRHE PROTECTOFIER
7256-BT-5NR PROTECTOFIER
7256-BT-5NRE PROTECTOFIER
7256-BT-5NRH PROTECTOFIER
7256-BT-5NRHE PROTECTOFIER
FORM 8966 TELE FAULT II FIRT OUTAGE
FORM 6642VL
FORM 6642VLT PROTECTOFIER
FORM 76057-B PROTECTOFIER
FORM 5909N-8 IGNITIFIER
PCI 6642VA PROTECTOFIER
PCI 6642VBT PROTECTOFIER
PCI 6642VLT PROTECTOFIER
PCI 6642VT PROTECTOFIER
PROTECTION CONTROLS INC公司主要有如下產品:
火焰檢測器
燃燒控制器
繼電器
點火變壓器
安全控制器
U-V SCANNER
......
常用型號:
火焰檢測器:
P-C II U-V SCANNER
P-C II W U-V SCANNER
P-C II WRA U-V SCANNER
P-CII U-V SCANNER
P-CII W U-V SCANNER
P-CII WRA U-V SCANNER
P-CIIW U-V SCANNER
P-CIIWRA U-V SCANNER
繼電器:
2AC 200V RELAY
2AC 230V RELAY
ACF RELAY
TCL RELAY
LR100 RELAY
ACF CHECK RELAY
SS100A FLAME PAK
SS108A FLAME PAK
DP100 DELAY PAK
SST PLUG-IN PURGE TIMER
U300A TIMOFIER
U300M TIMOFIER
變壓器, 點火變壓器:
A06 IGNITION TRANSFORMER
A10 IGNITION TRANSFORMER
A10-LA2 IGNITION TRANSFORMER
C06-SA6 IGNITION TRANSFORMER
SS3CP TRANSFORMER
SS3CPD TRANSFORMER
SS4CP TRANSFORMER
燃燒控制器:
6642VA PROTECTOFIER
6642VB PROTECTOFIER
6642VBL PROTECTOFIER
6642VBLNR PROTECTOFIER
6642VBLT PROTECTOFIER
6642VBLT/NR PROTECTOFIER
6642VBNR PROTECTOFIER
6642VBT/NR PROTECTOFIER
6642VL PROTECTOFIER
6642VLT PROTECTOFIER
6642VT PROTECTOFIER
FORM 7256-AH PROTECTOFIER
7256-AHE PROTECTOFIER
7256-B PROTECTOFIER
7256-B10 PROTECTOFIER
7256-B10E PROTECTOFIER
7256-B10H PROTECTOFIER
7256-B10HE PROTECTOFIER
7256-B10NR PROTECTOFIER
7256-B10NRE PROTECTOFIER
7256-B10NRH PROTECTOFIER
7256-B10NRHE PROTECTOFIER
7256-B5 PROTECTOFIER
7256-B5E PROTECTOFIER
7256-B5H PROTECTOFIER
7256-B5HE PROTECTOFIER
7256-B5NR PROTECTOFIER
7256-B5NRE PROTECTOFIER
7256-B5NRH PROTECTOFIER
7256-B5NRHE PROTECTOFIER
7256-BE PROTECTOFIER
7256-BH PROTECTOFIER
7256-BHE PROTECTOFIER
7256-BNR PROTECTOFIER
7256-BNRE PROTECTOFIER
7256-BNRH PROTECTOFIER
7256-BNRHE PROTECTOFIER
7256-BT-10NR PROTECTOFIER
7256-BT-10NRE PROTECTOFIER
7256-BT-10NRH PROTECTOFIER
7256-BT-10NRHE PROTECTOFIER
7256-BT-15NR PROTECTOFIER
7256-BT-15NRE PROTECTOFIER
7256-BT-15NRH PROTECTOFIER
7256-BT-15NRHE PROTECTOFIER
7256-BT-5NR PROTECTOFIER
7256-BT-5NRE PROTECTOFIER
7256-BT-5NRH PROTECTOFIER
7256-BT-5NRHE PROTECTOFIER
FORM 8966 TELE FAULT II FIRT OUTAGE
FORM 6642VL
FORM 6642VLT PROTECTOFIER
FORM 76057-B PROTECTOFIER
FORM 5909N-8 IGNITIFIER
PCI 6642VA PROTECTOFIER
PCI 6642VBT PROTECTOFIER
PCI 6642VLT PROTECTOFIER
PCI 6642VT PROTECTOFIER
Protectofier 6642 - Combustion Safeguards
Operate with Flame Rod/P-C II Scanner
6642 Features
Modularized Multi-Burner Control
Time Proven Plug-in Solid State FLAME-PAK Amplifier
Plug-in, Interchangeable Relays
Plug-in Power Transformer
Flame Rod/Ultra-Violet Sensing. Independent simultaneously using same FLAME-PAK Amplifier.
FORM 6642VA
Basic combustion safeguard model
FORM 6642VB
Breaker - lockout switch model
Required fautomatic lighted installations. System "latches out" after failure to light within ignition trial time cannot attempt restart until switch is manually reset.
Standard ignition trial time is 15 seconds. Also available in 10-second 5-second trial time.
Form 6642VBNR - Automatic only Non-relight.
FORM 6642VL
Load relay - included fall multi-burner models
FORM 6642VT
Timofier model plugin, fixed time assembly.
The timofier provides purge time ignition trial time. The ignition trial time is deducted from the mottime cycle (1/2, 1, 1-1/4, 2, 3, 4, 6 minutes available fmanual automatic models; 10 minutes fmanual model only) to purge the time.
Standard ignition trial time is 15 seconds. Also available in 10-second 5-second trial time.
Specify both purge ignition times.
Purge time shall allow system to have a minimum of four fresh air changes.
FORM 6642VBL
Combines features of Breaker Load relay models described above.
Form 6642VBLNR - Automatic only Non-relight.
FORM 6642VBT
Combines features of Breaker Timofier models described above.
Form 6642VBTNR - Automatic only Non-relight.
FORM 6642VLT
Combines features of Load relay Timofier models described above.
FORM 6642VBLT
Combines features of Breaker, Load relay, Timofier models described above.
Form 6642VBLTNR - Automatic only Non-relight.
FORM 6642FF
Full Feature Combustion Safeguard including:
Proof of Closure
Proof of High Fire Purge
Purge Timing (In 15 sec. increments, 7 min. 45 sec. max)
Proof of Low Fire Start
Ignition Trial Timing (Pilot) 10 sec.
Pilot Interrupt Timing (Main burner ignition trial) 10 15 sec.
Alarm output if the safety interlocks (limit switches) flame failure causes shutdown.
Relay contacts available to drive actuatto high fire fpurge, low fire fignition trial, control when main burner is proven.
Eight status lights
P-C II - Ultra-Violet Scanner
Detects any flame which contains ultra-violet
Features
High flame signal
Can be mounted in any position
Encapsulated senstube permanently sealed in gas tight housing
Operates with gas/oil flames
P-C II
Basic model.
Provided with an electrical connectfflexible metal conduit (3/8" max.)
P-C II W
Provided with 1/2" straight liquid-tite electrical connector.
P-C II WRA
Provided with a 1/2" right angle liquid-tite electrical connector.
Protectal Unified Control Panels
Single Multi-burner Packaged Combustion Protection
Protectal Unified Features
Ready to install
No additional components necessary
Prewired fimmediate operation
Protectal Unified 62019
Form 6642VA Protectofier*
Plug-in solid state electronic FLAME-PAK
Plug-in ACF relays
START pushbutton
Signal light to indicate flame
Ignition transformer (optional)
Dust-tight steel enclosure
*Available options include Form "B" Protectofier fautomatic operation safety requirements such as non-relight, low fire start, interrupted pilot.
Protectal Unified 62021
Form 6642VT Protectofier with plug-in TIMOFIER fpurge ignition trial, plug-in solid state electronic FLAME-PAK plug-in ACF relays
Burner Off/Run/Ignition switch
Signal light to indicate flame
Signal light to indicate timer operation
Ignition transformer (optional)
Dust-tight steel enclosure
*Available options include Form "B" Protectofier fautomatic operation safety requirements such as non-relight, low fire start, interrrupted pilot.
Standard Complete Unified 82064 82065
Compact Control Panel with same features as Unified Panel - plus MotControl
Complete Unified 63031 63032
Compact Control Panel with same features as Standard Complete Unified Panel - except customized to perform a wide range of additional control functions.
Ignitifier I 5909N - motor-driven Multi-Burner igniter control
Automatically fires up to 40 burners... in seconds!
Features
Improved Safety Performance: One unit automatically fires up a complete network of gas burners in ovens, furnaces, boilers heat treating systems.
High-Speed Spark Ignition: 40 burners within 3 seconds
No Spark Gap Loss: Positive contact-wiper switching design eliminates arcing gap wasted energy. - puts full voltage spark at burner!
Interchangeable Components: When systems are enlarged, Rotunit spark electrode end plates can be replaced with higher capacity units to accommodate additional burners.
How it works...
When the Ignitifier is energized by a START button, a motorized double-end shaft rotates its wiping contact against a series of stationary contact tips (one feach Ignitin the system). This causes a high voltage impulse from an ignition transformer to be fed to each burner spark electrode, immediately ignites the gas-air mixture of each burner position (gas-air mixture has been simultaneously released with actuation of the START button). The unit repeats until all burners are ignited.
Ignitifier II 6954 - Solid-State Multiple Ignition System
Features One-Wire Distribution: One single compact unit ignites up to 30 (more) spark ignited gas burners all at the same time instaneously.
Features
All Electric
Instantaneous
Dependable
Low Primary Current fmany burners
No need fspecial high current switches, contactors power supply
No mechanical action
No need fmultiplicity of complex high voltage wiring; requires only single wire service to electrical box similar connections. Fovens, furnaces, boilers, etc.
Compare to rotary other mechanical systems:
Solid-state dependability, compactness
Can be installed fcontinuous operation
No moving parts, no mechanical wear
Instant, simultaneous sparking at all points
Ignites unbalanced mixtures more effectively
Saves on equipment installation time
Less space, less wiring, less conduit
Maintenance practically eliminated
Simple, quality components
Ignitifier III 7759
Features Spark Blind Ignit(single burner)
Tele-Fault II 8966 - First-Outage Fault Finder
Unequalled reliability operating savings fmonitoring equipment in heating processing systems. Monitors up to 8 read-out positions.
Features
Single Wire Connections
No Additional Relays
Compact Design 1/4 Din Size
Start-Up Status Display
First-Outage Readout
Power Interruption Indicator
Lights Pushbuttons